Last Updated on September 6, 2020 by
Coleman Spas are programmed to filter twice a day. The first cycle starts six minutes after the spa is turned on, and the second cycle runs 12 hours later. The default filtering is for two hours, but you can change this to suit your needs. Filtration time can be anywhere from one to six hours. I bought my Intex Pure Spa from Walmart in June 2017 and ran it for 3 months until it crapped out with the E90 code in August. I let it sit until May 2018 and decided to delve into it. This is where I found the issue is inside the pump on the bottom of the unit. The pump has. Jacuzzi Whirlpool. OH = Overheat Protection (Heater is deactivated, pumps low speed is activated). COOL = Spa water is more than 20° F cooler than the temperature set point. FLO. = Flow Switch (heater is deactivated. Pump may also be deactivated). Hold = Panel sensors have been pressed too many times in a short period of time. HOT = Circuit Board temperature has exceeded acceptable limit.
How to Solve Intex PureSpa hot tub error code E90 & E96? Hey, hot tub owners today we are going to present you if you are getting alarm code E90 is displayed on your Intex PureSpa control panel then how to guaranteed troubleshoot it and what does it mean.
Lets Figure Out:
There are several error codes you might see on your Intex PureSpa inflatable hot tublike e90, e94, e96, e95, e98, e99. If you are facing any of these error codes, don't worry our full error code troubleshooting guide will help you to solve all these error codes.
So, lets get start:
Intex PureSpa hot tub error code e90
Clownfish voice changer app download. What does error code e90 mean and how to solve it on Intex pure spa hot tub? So, the answer is here.
No Water Flow Through Filter Cartridges
If you getting an error code of E90 on your Intex Inflatable hot tub control panel it means no water is flowing through the system. Check the attached troubleshooting Manual. For solving this problem all you have to do is following these steps:
- Clean the filter cartridge of the hot tub or replace it with a new one.
- If E90 persists, check and ensure there is no debris inside the spa tub inlet and outlet grids. If there is debris inside, unscrew the spa inlet/outlet grid with a screwdriver. Clean and replace it back.
- Make sure the spa water is clean and sanitized.
If you don't want to see again E90 Error code on your Intex Pure Spa Hot tub make sure these 2 things:
- Water is filled to the recommended level.
- The filter cartridge is clean and properly installed. Turn off or unplug the control unit. Remove the filter cartridge assembly from the spa tub. Turn on the control unit and activate the filtration to make sure there is water flowing through.
How to Solve Intex PureSpa hot tub error code e96
If you are facing an error code of E96 on your Intex Inflatable hot tub and want to troubleshoot it then you are at the right place.
The error code E96 which displays on your Intex hot Tub Control Panel that means your Spa is facing a system error. Facefilter pro 3 05. If you getting this problem all you have to do is:
- Turn off the hot tub system and unplug it.
- After some time plug the Spa unit back in and restart your Intex hot tub system.
If the error is still showing you follow these steps to stop the error.
- Turn hot tub off and unplug it from the electricity source.
- After unplugging it, unscrew the B and C connection until water starts to leak out.
- Do not unscrew the connection to the point that they come off of the tub as you can lose all the water in the tub.
- Loosening them until the leak will release any air from the control base. Tighten the connections and restart the unit.
Intex Hot Tub LED error Codes Chart With Troubleshooting
In this Intex Hot Tub Manual error code chart you can find every error code you are facing in your Intex portable Spa:
other Intex hot tub errors Codes and their solutions
Intex PureSpa Inflatable Hot Tub Error Code E94
If your Intex PureSpa inflatable hot tub displaying an alarm error code E94 on the control panel, it means the water temperature of your hot tub is too low. If Intex hot tub error code E94 appears, unplug your hot tub and plug back into the GFCI/RCD plug and restart the hot tub when the spa water temperature is higher than 39ºF.
Follow steps for troubleshoot E94 code:
- If the ambient temperature is below 39°F (4°C), we recommend not to use the spa.
- Turn off and unplug the control unit, add some warm water to raise the spa water temperature above 5°C (41°F), then press the button to heat up the water to the desired temperature.
- Press the temperature increase button to set the desired water temperature.
- If the problem persists, contact Intex Service center
Getting Intex Hot Tub Error Code E95?
Don't worry if you are getting Intex hot tub error code E95. It means that the water temperature is too hot. If you are facing this problem let the water temperature cool down to the highest temperature of the hot tub which is 104F or below.
Follow these steps for solving E95 error code:
- Turn off and unplug the control unit.
- When the water has cooled down, plug the GFCI/RCD and restart the system again.
- Turn the heater off, then press the filter and bubble buttons to lower the water temperature.
- If the problem persists, contact Intex Service Center.
Intex Hot Tub Alarm Code E98: Solution
If you are experiencing alarm code E98 is displayed on your hot tub control panel, it means the spa has encountered either water or ambient temperature of 55℃ (131ºF) or above
The solution to this problem is very simple, first press the 'RESET' button on the side of the spa control unit using a small and thin object till the E98 alarm stop, then unplug and plug back in the RCD to restart the system.
If E98 stillshown after several reset attempt, follow these instructions:
- Unplug the power cord and disconnect the control base from the tub. Flip over the control base to locate the reset button box.
- Unscrew the two screws.
- Pull out the reset button box and unscrew the two screws on the bottom of the box.
- Take out the cover and pull out the white thermal protector.
- Press the black button to check if it goes down and up or not.
- Make sure the black rubber cover is not out of place and sitting inside the housing.
Here is the complete solution Intex Hot Tub Alarm Code E98 guide.
Intex Hot Tub Error Code E99
Toshiba tec sx5 driver for mac. If your Intex hot tub pure spa throwing an error code of E99 it means that your hot tub experiencing an internal error. If you want to solve this error all you have to do is go and check your hot tub by the nearest Intex customer service executive.
intex pure spa reset button
In this article, we talk about the Intex hot tub Reset button but we didn't talk about where is the location of the pure spa reset button. Intex hot tub's RESET button is located on the side of the spa control panel. If you facing any error code press the reset button and restart the unit.
Conclusion
If you are facing any problem or issue with your Intex hot tub or your Intex hot tub throwing any error E90, E94, E95, E96, E98, or E99. Try to troubleshoot with our methods with our guide. Or if you don't know how to solve it go and check your Intex hot tub by nearest Intex customer support team.
Still, any question you have in mind please feel free to ask in the comment section below. Your comment is highly appreciated by us.
Read Also: How to find a leak in an inflatable hot tub – Step By Step Guide
There may be a number of reasons why your heater pump is displaying an error code. The following is a list of error codes, the reason behind them and how they can be solved.
Select Your Error Code:Coleman Spa Symptom Troubleshooting. Possible Causes. Possible Solutions. System / Power Problems.
E01
← swipe →
Description | Cause | Solution |
---|---|---|
Sensor Error | The water flow sensors' flags didn't come back into the correct position. | Unplug the pump unit, lightly strike the side of it and then plug it back in. |
Water Flow Error | Electrical issue. Can occur when the spa is not plugged into a mains socket. May also be an issue with the RCD socket. | Plug the pump unit directly into a mains socket and not into an extension lead. |
E02
← swipe →
Description | Cause | Solution |
---|---|---|
Water Flow Error | The stopper caps are still inside the spa. | Remove the stopper caps before heating your Lay-Z-Spa. If you're unsure how to remove them, refer to the assembly section within the Lay Z Spa Owner's Manual. |
Water Flow Error | Filter cartridges are dirty | Remove the filter cartridges from the pump and press the filter or heat button. If no alarm appears, you will need to clean or replace the filter cartridges. |
Water Flow Error | Filter housing is restricting flow | Remove the filter cartridges from the pump and press the filter or heat button. If no alarm appears, you will need to clean or replace the filter cartridges. |
Water Flow Error | Debris screens are blocked. | Ensure that the debris screens are clear of debris. |
Pipes within the liner are kinked or bent. | Using your hands, check the condition of the pipes within the liner. | |
Water Flow Error | Water flow sensors not working | If the above troubleshooting has not resolved the problem, the water flow sensors may not be working. Please contact us for more help with this |
E02 Error Code Troubleshooting download
E03
← swipe →
Description | Cause | Solution |
---|---|---|
Temperature too low | Normally caused when the Lay Z Spa pump has been used in temperatures below 4ºC. | The pump will only operate when the ambient temperature is above 4ºC. |
Temperature too low | The pump thermometer is broken. | If your pump is displaying this message and the ambient temperature is above 4ºC. Please contact us for more help. |
E04
← swipe →
Description | Cause | Solution |
---|---|---|
Temperature too high | The pump unit has overheated. | Place the stopper caps inside the spa, disconnect the pump unit, and bring the pump unit inside to cool down. |
Temperature too high | The water temperature is over 50ºC (122ºF). | The Lay-Z-Spa is not designed to operate with water temperatures exceeding 40ºC (104ºF). Unplug the pump and plug it back in once the water temperature has reached 38ºC (100ºF) or lower. IMPORTANT: Before you restart the pump, press the reset button. |
Temperature too high | The thermostat needs resetting. |
|
E05
← swipe →
Description | Cause | Solution |
---|---|---|
Temperature too high | The thermostat is broken. | If the troubleshooting has been completed without success, please contact usfor more help with this |
Pump needs to be reset. |
| |
Pump unit needs to be cleaned | Try the back wash procedure. | |
Not enough power to the pump. | Ensure the pump unit is plugged into a mains socket and not an extension lead. | |
Pump may be faulty. | If the troubleshooting has been completed without success, please contact usfor more help with this |
E06
← swipe →
Description | Cause | Solution |
---|---|---|
The power port has experienced a temporary current variation. | Unplug the pump and then plug the pump back in. | |
Pump may be faulty. | If the troubleshooting has been completed without success, please contact usfor more help with this |
E07
← swipe →
Description | Cause | Solution |
---|---|---|
Please contact us regarding this problem. | If the troubleshooting has been completed without success, please contact usfor more help with this |
E08
← swipe →
Description | Cause | Solution |
---|---|---|
The thermostat needs resetting. |
|
E09
← swipe →
Description | Cause | Solution |
---|---|---|
Fuse Failure. | Internal fuse failure or has become disconnected within the pump. |
|
E10
Coleman Spas Hot Tub Error Codes
← swipe →
Coleman Spas Hot Tub By Maax
Description | Cause | Solution |
---|---|---|
High salt alarm. | Alarm where too much salt has been added to the spa or a large amount of water has evaporated. |
|
E11
← swipe →
Description | Cause | Solution |
---|---|---|
Low salt alarm. | Alarm for low salt levels within the spa. This means the spa requires further salt to be added. |
|
E12
← swipe →
Description | Cause | Solution |
---|---|---|
Water Leakage. | Error code for an issue with water leaking within the body of the pump. |
|
E13
Coleman Spas Hot Tub Error Codes Free
Coleman Spas Hot Tub Manuals
https://vividfree.mystrikingly.com/blog/how-do-i-open-zip-files-in-windows-10. ← swipe →
Description | Cause | Solution |
---|---|---|
Signal within the pump. | Error code for issue where the electrical signal within the pump body between the control panel and power board has become disconnected. |
|
GCF
← swipe →
Description | Cause | Solution |
---|---|---|
Not grounded/earthed correctly. | An issue with your extension lead or power supply. | Remove extension lead or get a qualified electrician to check your socket & power supply. If this does not resolve the issue, please contact us. |
Backwash Procedure
Attach the stopper caps to the inside of the liner and then remove the Lay-Z-Spa pump unit from the liner (you can do this by unscrewing the 3 couplings ‘A, B and C').
https://coolefile121.weebly.com/juvenile-400-degreez-zip.html. Using a hosepipe, flush water backwards through the pump. Water should go through pipe ‘B' and come out of pipe ‘C'.
Coleman Spas Hot Tub Error Codes 2017
After a few minutes, flush the water in the opposite direction for about 2 minutes (through pipe ‘C' and out of pipe ‘B').
Coleman Spas Hot Tub Error Codes Generator
If you have a Hydro Jet Lay-Z-Spa, unfortunately, the backwash procedure will be a little tricky. These are not constructed like the other models of the Lay-Z-Spa. please contact us